DCT-W10-3 TIMBER FRAMED BRICK VENEER WALL WITH INTERNAL INSULATION (PIR)

Timber framed brick veneer wall, insulated within the frame and internally with DCT PIR Silver, protected by vapour permeable, air & water tight ProctorWrap sarking fixed to the outside of the frame.

By |2024-02-13T10:20:03+11:00February 12th, 2024|Comments Off on DCT-W10-3 TIMBER FRAMED BRICK VENEER WALL WITH INTERNAL INSULATION (PIR)

DCT-W21-2 LIGHTWEIGHT THERMALLY BROKEN STEEL FRAME WALL (PIR INTERNAL INSULATION)

A lightweight clad steel frame wall insulated by noncombustible DCT VulcanWool and a continuous XPS thermal break strip fixed between the cladding and the frame to form a drained and vented cavity. The frame and insulation are protected by a vapour permeable, air and water tight ProctorPassive sarking. The interior DCT PIR Silver insulation is mechanically fixed directly to the interior face of the frame and must be taped and sealed to form a continuous air and vapour control layer. As the thermal break strip and PIR insulation are both deemed combustible, this solution is never recommended for type A or B non-combustible wall construction.

By |2024-02-13T10:18:16+11:00February 12th, 2024|Comments Off on DCT-W21-2 LIGHTWEIGHT THERMALLY BROKEN STEEL FRAME WALL (PIR INTERNAL INSULATION)

DCT-W42-2 EXTERNALLY INSULATED CLT WITH BRICK VENEER (NOT FIRE PROTECTED)

Mass timber CLT made water and air tight by the self-adhered vapour permeable ProctorPassive Wraptite SA, externally insulated with a non-combustible DCT VulcanWool stonewool insulation, protected by a brick veneer cladding. The insulation is mechanically fixed with minimal thermal bridging, to form a continuous external insulation layer. As the CLT is not classified as fire protected timber this solution is not suitable for type A or B non-combustible wall construction.

By |2023-12-28T10:54:38+11:00December 20th, 2023|Comments Off on DCT-W42-2 EXTERNALLY INSULATED CLT WITH BRICK VENEER (NOT FIRE PROTECTED)

DCT-W41-5 EXTERNALLY INSULATED CLT WITH RAINSCREEN CLADDING WITH GEOVAP

CLT mass timber wall made water, air, and vapour tight by the ProctorGeo Vap 120 air and vapour retarder, externally insulated with a non-combustible DCT VulcanWool stonewool insulation, protected by a rainscreen cladding supported by the Nvelope engineered helping hand sub-framing system. The insulation is mechanically fixed with minimal thermal bridging, to form a continuous external insulation layer. As the CLT is not classified as fire protected timber this solution is not suitable for type A or B non-combustible wall construction.

By |2023-12-28T10:52:44+11:00December 20th, 2023|Comments Off on DCT-W41-5 EXTERNALLY INSULATED CLT WITH RAINSCREEN CLADDING WITH GEOVAP

DCT-W41-4 EXTERNALLY INSULATED CLT WITH RAINSCREEN CLADDING (NOT FIRE PROTECTED)

Mass timber CLT made water and air tight by the self-adhered vapour permeable ProctorPassive Wraptite SA, externally insulated with a non-combustible DCT VulcanWool stonewool insulation, protected by a rainscreen cladding supported by the Nvelope engineered helping hand sub-framing system. The insulation is mechanically fixed with minimal thermal bridging, to form a continuous external insulation layer. As the CLT is not classified as fire protected timber this solution is not suitable for type A or B non-combustible wall construction.

By |2023-12-28T10:50:06+11:00December 20th, 2023|Comments Off on DCT-W41-4 EXTERNALLY INSULATED CLT WITH RAINSCREEN CLADDING (NOT FIRE PROTECTED)

DCT-W11-7 LIGHTWEIGHT CLAD TIMBER FRAME WALL WITH EXTERNAL DCT VULCANWOOL INSULATION

Timber frame wall with a rigid sheathing board made water and air tight by the self-adhered vapour permeable ProctorPassive Wraptite SA, externally insulated with a non-combustible DCT VulcanWool stonewool insulation, protected by a lightweight cladding on battens. The insulation is mechanically fixed to the sheathing board with minimal thermal bridging, to form a continuous external insulation layer. Additional insulation within the frame would only be considered having assesed condensation risk.

By |2023-12-28T10:44:38+11:00December 19th, 2023|Comments Off on DCT-W11-7 LIGHTWEIGHT CLAD TIMBER FRAME WALL WITH EXTERNAL DCT VULCANWOOL INSULATION