DCT-W07-1 EXTERNALLY INSULATED RAINSCREEN MASONRY WALL (PIR)

A single skin masonry wall externally insulated with a foil faced rigid thermoset PIR insulation protected by a rainscreen cladding supported by the Nvelope engineered helping hand sub framing system. The insulation is mechanically fixed directly to the exterior face of the masonry, with minimal thermal bridging, and must be taped and sealed to form a continuous air, vapour and water control layer. As the PIR insulation is deemed combustible, this solution is never recommended for type A or B non-combustible wall construction.

By |2023-08-15T15:24:30+10:00May 28th, 2020|Comments Off on DCT-W07-1 EXTERNALLY INSULATED RAINSCREEN MASONRY WALL (PIR)

DCT-W06-1 INTERNALLY INSULATED MASONRY WALL (PIR)

An exposed single skin masonry wall such as a concrete tilt slab internally insulated with a foil faced rigid thermoset PIR insulation. The insulation is mechanically fixed directly to the interior face of the masonry, with minimal thermal bridging, and must be taped and sealed to form a continuous air and vapour barrier preventing internal moisture vapour from condensing on masonry at below dew point temperature. This solution is often used as a compromise where external insulation is not an option. As the PIR insulation is deemed combustible, this solution can only ever be used in type A or B construction is approved as part of a fire engineered performance solution.

By |2023-08-15T15:22:34+10:00May 28th, 2020|Comments Off on DCT-W06-1 INTERNALLY INSULATED MASONRY WALL (PIR)