Metal Roofing
Products
- DCT-R01-1[C] PITCHED METAL ROOF WITH HORIZONTAL CEILING (PIR)Commercial steel framed pitched metal roof with a suspended horizontal ceiling. The rigid thermoset PIR insulation board forms a continuous air and vapour control layer at the ceiling with further ceiling insulation added above. The vapour permeable sarking, separated from the roof sheet by a drainage batten provides drainage of any moisture or condensate forming below the roof sheet. Suitable for ventilated and unventilated roofs.DCT-R01-1[R] RESIDENTIAL METAL ROOF WITH HORIZONTAL CEILING (PIR)Residential timber structure metal roof with a suspended horizontal ceiling. The rigid thermoset PIR insulation board forms a continuous air and vapour control layer at the ceiling with further ceiling insulation added above. The vapour permeable sarking, separated from the roof sheet by a drainage batten provides drainage of any moisture or condensate forming below the roof sheet. Suitable for ventilated and unventilated roofs.DCT-R01-2[C] PITCHED METAL ROOF WITH HORIZONTAL CEILING (SMARTVAP)Commercial steel framed pitched metal roof with a suspended horizontal ceiling. The rigid thermoset PIR insulation board forms a continuous air and vapour control layer at the ceiling with further ceiling insulation added above. The vapour permeable sarking, separated from the roof sheet by a drainage batten provides drainage of any moisture or condensate forming below the roof sheet. Suitable for ventilated and unventilated roofs.DCT-R01-2[R] RESIDENTIAL PITCHED METAL ROOF WITH HORIZONTAL CEILING (SMARTVAP)Residential timber structure pitched metal roof with a suspended horizontal ceiling. The SmartVap intelligent air barrier membrane above the ceiling forms a continuous air and vapour control layer with ceiling insulation above. The ProctorWrap vapour permeable sarking, separated from the roof sheet by a drainage batten provides drainage of any moisture or condensate forming below the roof sheet. Suitable for ventilated and unventilated roofs.DCT-R02-1[R] RESIDENTIAL METAL ROOF WITH CATHEDRAL CEILING BELOW RAFTERS (PIR)Residential timber structure metal roof with a cathdral ceiling below the rafters. The rigid thermoset PIR insulation board forms a continuous air and vapour control layer at the ceiling with further ceiling insulation added above. The vapour permeable sarking, separated from the roof sheet by a drainage batten provides drainage of any moisture or condensate forming below the roof sheet. Suitable for ventilated and unventilated roofs.DCT-R02-2[R] RESIDENTIAL METAL ROOF WITH CATHEDRAL CEILING BELOW RAFTERS (SMARTVAP)Residential timber structure metal roof with a cathedral ceiling below the rafters. The SmartVap intelligent air barrier membrane at the ceiling forms a continuous air and vapour control layer with further ceiling insulation added above.DCT-R02-3(R)RESIDENTIAL METAL ROOF WITH CATHEDRAL CEILING BELOW RAFTERS AND MEMBRANE BELOW BATTENS (SMARTVAP)Residential timber structure metal roof with a cathedral ceiling below the rafters. The SmartVap intelligent air barrier membrane at the ceiling forms a continuous air and vapour control layer with ceiling insulation added above. The vapour permeable sarking is draped over the rafters, separated from the roof sheet by the roof battens providing for drainage of any moisture or condensate forming below the roof sheet. Suitable for ventilated and unventilated roofs.DCT-R07-1 STANDING SEAM EXTERNALLY INSULATED METAL ROOF (PIR)A "warm roof" design continuously insulated by a rigid PIR insulation installed above the roof sheathing board. The ProctorGeo HC9 drainage mat installed directly below the standing seam roofing, and above the self-adhered vapour permeable Wraptite SA sarking, provides for drainage and acoustic attenuation of rain noise.DCT-R08-1 VENTILATED STANDING SEAM METAL ROOF INTERNALLY INSULATED (PIR)A "cold roof" design continuously ventilated from ridge to eaves below the roof sheathing board with a rigid thermoset DCT PIR insulation board forming a continuous air and vapour control layer at the ceiling with further ceiling insulation added between the rafters. The ProctorGeo HC9 drainage mat installed directly below the standing seam roofing, and above the self-adhered vapour permeable Wraptite SA sarking, provides for drainage and acoustic attenuation of rain noise.DCT-R08-2 VENTILATED STANDING SEAM METAL ROOF INTERNALLY INSULATED (SMARTVAP)A "cold roof" design continuously ventilated from ridge to eaves below the roof sheathing board. The SmartVap intelligent air barrier membrane above the ceiling forms a continuous air and vapour control layer with further ceiling insulation added between the rafters. The ProctorGeo HC9 drainage mat installed directly below the standing seam roofing, and above the self-adhered vapour permeable Wraptite SA sarking, provides for drainage and acoustic attenuation of rain noise.DCT-R20-1 METAL ROOF OVER AN INSULATION BLANKET AND RIGID XPS THERMAL BREAKS (HC9 SPACER MAT)Pitched metal cathedral roof externally insulated with a continuous vapour and air retarder faced mineral fibre insulation blanket supported by a safety mesh or strapping. The full thickness of the insulation is maintained using a rigid DCT XPS thermal break at each purlin. The ProctorGeo HC9 drainage mat installed between the roof sheet, and above the vapour permeable ProctorWrap HTS sarking, provides for drainage and acoustic attenuation of rain noise.DCT-R20-2 METAL ROOF EXTERNALLY INSULATED BY RIGID PIR INSULATION BOARDPitched metal cathedral roof externally insulated with a continuous vapour and air tight rigid thermoset DCT PIR insulation board supported by purlins, a safety mesh or strapping. The ProctorGeo HC9 drainage mat installed between the roof sheet, and above the vapour permeable ProctorWrap HTS sarking, provides for drainage and acoustic attenuation of rain noise.DCT-R20-3 METAL ROOF OVER AN INSULATION BLANKET AND RIGID XPS THERMAL BREAKS (DRAINAGE BATTEN)Pitched metal cathedral roof externally insulated with a continuous vapour and air retarder faced mineral fibre insulation blanket supported by a safety mesh or strapping. The full thickness of the insulation is maintained using a rigid DCT XPS thermal break at each purlin. The ProctorPassive Drainage Batten installed above the vapour permeable ProctorWrap HTS sarking at each purlin, provides for drainage, ventilation and separation.DCT-R20-4 COMMERCIAL METAL ROOF WITH FOIL FACED INSULATION BLANKET, ROOF SPACES AND VAPOUR PERMEABLE MEMBRANE (VENTILATION BATTEN)Commercial metal roof externally insulated with a vapour barrier faced mineral fibre insulation blanket supported by a safety mesh. The full thickness of the insulation is maintained using structural spacers at each purlin. The ProctorVent VB20 Ventilated Batten installed below the roof sheet, and above the vapour permeable ProctorWrap HTS sarking, provides for drainage and ventilation.DCT-R20-5 COMMERCIAL METAL ROOF WITH FOIL FACED INSULATION BLANKET, ROOF SPACES AND VAPOUR PERMEABLE MEMBRANE (HC8 SPACER MAT)Commercial metal roof externally insulated with a vapour barrier faced mineral fibre insulation blanket supported by a safety mesh. The full thickness of the insulation is maintained using structural spacers at each purlin. The ProctorGeo HC8 spacer mat installed below the roof sheet, and above the vapour permeable ProctorWrap HTS sarking, provides for drainage, ventilation and acoustic attenuation.DCT-R41-1 PITCHED CLT METAL ROOF INSULATED BETWEEN COUNTER BATTENSPitched CLT roof structure insulated with a low density mineral fibre insulation fitted between timber counter battens. The vapour permeable ProctorWrap sarking draped under roofing battens provides drainage of any moisture or condensate forming below the metal roof sheet.DCT-R41-2 PITCHED CLT METAL ROOF CONTINUOUSLY INSULATED EXTERNALLY (PIR)Pitched CLT roof structure externally insulated with a continuous rigid DCT PIR insulation board fitted below counter battens. The vapour permeable ProctorWrap sarking draped under roofing battens provides drainage of any moisture or condensate forming below the metal roof sheet.DCT-R41-3 PITCHED CLT METAL ROOF CONTINUOUSLY INSULATED EXTERNALLY (VULCANWOOL)Pitched CLT roof structure externally insulated with a continuous high-density non-combustible DCT Vulcanwool insulation board fitted below counter battens. The vapour permeable ProctorWrap sarking draped under roofing battens provides drainage of any moisture or condensate forming below the metal roof sheet.DCT-R44-1 FLAT CLT WITH METAL ROOF, SPACERS AND DCT VULCANWOOLFlat CLT roof structure protected by ProctorPassive Wraptite SA, externally insulated with a continuous high density non-combustible DCT VulcanWool insulation board fitted between a structural roof spacer. The vapour permeable ProctorWrap HTS sarking with ProctorVent VB20 Ventilation batten provides drainage of any moisture or condensate forming below the metal roof sheet.DCT-R50-1 SWIMMING POOL ROOF EXTERNALLY INSULATED BY RIGID XPS INSULATION BOARDSwimming pool or aquatic centre roof externally insulated with a continuous closed cell moisture resistant DCT XPS insulation board above a ProctorGeo Vap120 vapour retarder supported by purlins, a safety mesh, roof deck or strapping. The ProctorGeo HC9 drainage mat installed between the roof sheet, and above the vapour permeable ProctorWrap HTS sarking, provides for drainage and acoustic attenuation of rain noise. The continuous external moisture resistant insulation maintains the roof structure at indoor temperature which should be above dew point.