Timber Frame Walls

Products

  1. DCT-W10-1 TIMBER FRAMED BRICK VENEER WALL
    Timber framed brick veneer wall, insulated within the frame and protected by a vapour permeable, air & water tight ProctorWrap sarking fixed to the outside of the frame.
  2. DCT-W10-2 TIMBER FRAMED BRICK VENEER WALL WITH INTERNAL AIR BARRIER (SMARTVAP)
    Timber framed brick veneer wall, insulated within the frame and protected by vapour permeable, air & water tight ProctorWrap sarking fixed to the outside of the frame. The SmartVap intelligent air barrier membrane installed to the inside of the timber frame.
  3. DCT-W10-3 featurred Image
    DCT-W10-3 TIMBER FRAMED BRICK VENEER WALL WITH INTERNAL INSULATION (PIR)
    Timber framed brick veneer wall, insulated within the frame and internally with DCT PIR Silver, protected by vapour permeable, air & water tight ProctorWrap sarking fixed to the outside of the frame.
  4. DCT-W11-1 LIGHTWEIGHT CLAD TIMBER FRAME WALL
    Lightweight clad timber framed wall, insulated within the frame and protected by a vapour permeable, air & water tight ProctorWrap sarking fixed to the outside of the frame with a vented and drained cavity.
  5. DCT-W11-2 LIGHTWEIGHT CLAD TIMBER FRAME WALL WITH INTERNAL AIR BARRIER (SMARTVAP)
    Lightweight clad timber framed wall, insulated within the frame and protected by vapour permeable water tight ProctorWrap sarking fixed to the outside of the frame with a vented and drained cavity. The SmartVap intelligent air barrier membrane installed to the inside of the timber frame forms a continuous air and vapour control layer and is best fixed behind a batten to forms a service cavity behind the plasterboard.
  6. DCT-W11-3 LIGHTWEIGHT CLAD EXTERNALLY INSULATED TIMBER FRAME WALL WITH SHEATHING BOARD (PIR)
    Timber frame wall with a rigid sheathing board made water and air tight by the self-adhered vapour permeable ProctorPassive Wraptite SA, externally insulated with a thermoset rigid DCT PIR insulation, protected by a lightweight cladding on battens. The insulation is mechanically fixed to the sheathing board with minimal thermal bridging, to form a continuous external insulation layer. Additional insulation within the frame would only be considered having assessed condensation risk.
  7. DCT-W11-4 LIGHTWEIGHT CLAD EXTERNALLY INSULATED TIMBER FRAME WALL WITH SHEATHING BOARD (DCT VULCANWOOL)
    Timber frame wall with a rigid sheathing board made water and air tight by the self-adhered vapour permeable ProctorPassive Wraptite SA, externally insulated with a non combustible Vulcanwool stone mineral fibre insulation, protected by a lightweight cladding on battens. The insulation is mechanically fixed to the sheathing board with minimal thermal bridging, to form a continuous external insulation layer. Additional insulation within the frame would only be considered having assessed condensation risk.
  8. DCT-W11-6 LIGHTWEIGHT CLAD TIMBER FRAME WALL
    Timber framed brick veneer wall, insulated within the frame and protected by a vapour permeable, air & water tight ProctorWrap sarking fixed to the outside of the frame.
  9. DCT-W11-7_Feature_Image
    DCT-W11-7 LIGHTWEIGHT CLAD TIMBER FRAME WALL WITH EXTERNAL DCT VULCANWOOL INSULATION
    Timber frame wall with a rigid sheathing board made water and air tight by the self-adhered vapour permeable ProctorPassive Wraptite SA, externally insulated with a non-combustible DCT VulcanWool stonewool insulation, protected by a lightweight cladding on battens. The insulation is mechanically fixed to the sheathing board with minimal thermal bridging, to form a continuous external insulation layer. Additional insulation within the frame would only be considered having assesed condensation risk.
  10. DCT-W11-8 iMAGE
    DCT-W11-8 RAINSCREEN TIMBER FRAME WALL WITH EXTERNAL DCT VULCANWOOL INSULATION (NVELOPE)
    Timber frame wall with a rigid sheathing board made water and air tight by the self-adhered vapour permeable ProctorPassive Wraptite SA, externally insulated with a non-combustible DCT VulcanWool stonewool insulation, protected by a rainscreen cladding supported by the Nvelope engineered helping hand sub-framing system. The insulation is mechanically fixed to the sheathing board with minimal thermal bridging, to form a continuous external insulation layer. Additional insulation within the frame would only be considered having assesed condensation risk.
  11. DCT-W12-1 REVERSE BRICK VENEER WALL
    Lightweight clad reverse brick veneer wall, insulated within the external framing and protected by vapour permeable water tight ProctorWrap sarking fixed to the outside of the frame with a vented and drained cavity.
  12. DCT-W13-1 LIGHTWEIGHT CLAD EXTERNALLY INSULATED TIMBER FRAME (XPS)
    Timber frame wall insulated extremally by a high compressive strength DCT XPS insulation made water and air tight by the self-adhered vapour permeable ProctorPassive Wraptite SA and protected by a lightweight cladding on battens. Additional insulation within the frame would only be considered having assessed condensation risk.
  13. DCT-W14-1 STANDING SEAM METAL CLAD INTERNALLY INSULATED TIMBER FRAME WALL
    Standing seam cladding on a thermally broken timber framed wall, insulated within the frame and protected by a vapour permeable, air & water tight ProctorWrap sarking fixed to the outside of the frame with a vented and drained cavity.
  14. DCT-W14-2 STANDING SEAM METAL CLAD INTERNALLY INSULATED TIMBER FRAME WALL (SMARTVAP)
    Standing seam cladding on a thermally broken timber framed wall, insulated within the frame and protected by a vapour permeable, air & water tight ProctorWrap sarking fixed to the outside of the frame with a vented and drained cavity. The SmartVap intelligent air barrier membrane installed to the inside of the timber frame forms a continuous air and vapour control layer and is best fixed behind a batten to form a service cavity behind the plasterboard.
  15. DCT-W14-3 STANDING SEAM METAL CLAD INTERNALLY INSULATED TIMBER FRAME WALL (PIR)
    Standing seam cladding on a thermally broken timber framed wall, insulated within the frame and protected by a vapour permeable, air & water tight ProctorWrap sarking fixed to the outside of the frame with a vented and drained cavity. The SmartVap intelligent air barrier membrane installed to the inside of the timber frame forms a continuous air and vapour control layer and is best fixed behind a batten to form a service cavity behind the plasterboard.
  16. DCT-W50-1 TIMBER FRAME SWIMMING POOL WALL INSULATED BY RIGID XPS INSULATION BOARD
    Lightweight clad indoor swimming pool timber framed wall, insulated within the frame by a vapour and moisture resistant closed cell DCT XPS insulation and protected by a vapour permeable water tight ProctorWrap sarking fixed to the outside of the frame with a vented and drained cavity formed by a thermal break strip. The ProctorGeo Vap120 air and vapour barrier membrane installed to the inside of the timber frame forms a continuous air and vapour control layer and is best fixed behind a batten to form a service cavity behind the internal linings.